Description: Trailing paddle up/down motor’s malfunction Detection timing <When FS-535 is installed> The trail edge paddle home sensor (PS20) is not blocked or unblocked even after the set period of time has elapsed after the trail edge paddle up/down motor (M15) is turned ON.
Causes: • Trail edge paddle up/down motor (M15) • Trail edge paddle home sensor (PS20) • FS control board (FSCB)
Remedy: 1 Check the connector between M15-relay CN122-FSCB CN12 for proper connection, and correct as necessary. 2 Check the connector of M15 for proper drive coupling, and correct as necessary. 3 Check the connector between PS20-FSCB CN50 for proper connection, and correct as necessary. 4 PS20 I/O check, sensor check FSCB CN50-6 (ON) FS-535 17-D 5 M15 operation check FSCB CN12-5 to 8 FS-535 5-D 6 Replace M15 7 Replace FSCB