Mã lỗi C3B03 — Konica-Minolta bizhub 654e

Code: C3B03

Description: IH malfunction (monitor) • Though the IH heater is ON, this status cannot be detected mechanically. (IH heater operation failure) • Though the IH heater is OFF, mechanically, the ON status is detected. (Malfunction of IH heater operation)
Causes: • Fusing unit • IH coil unit (IHC) • IH magnetic erasing board (IHMEB) • Noise filter (NF1) • Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHC, IHPU, IHMEB, NF1 and PRCB for proper connection and correct or change as necessary. 4 Check the marketing area of IHPU. If the marketing area is incorrect, replace IHPU for proper marketing area. 5 Replace the fusing unit 6 Replace IHC 7 Replace IHPU 8 Replace IHMEB 9 PRCB ICP15 conduction check 10 Replace PRCB 11 Replace NF1