Description: Tray 4 feeder up/down abnormality. The tray 4 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Causes: • Tray 4 upper limit sensor (PS27) • Tray 4 lift-up motor (M24) • Paper feed/transport drive board (PFTDB) • Printer control board (PRCB)
Remedy: 1 Check the connector between M24-PFTDB CN18 for proper connection and correct as necessary. 2 Check the connector of M24 for proper drive coupling and correct as necessary. 3 Check the connector between PS27-relay CN194-relay CN121B-PFTDB CN22 for proper connection and correct as necessary. 4 PS27 I/O check, sensor check PFTDB CN22-6 (ON) 8-X 5 M24 operation check PFTDB CN18-1 to 2 9-X 6 Replace M24 7 PFTDB ICP8 conduction check 8 Replace PFTDB 9 Replace PRCB