Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C1124 — Konica-Minolta bizhub 754

Code: C1124

Description: Sheet feeder up/down drive failure (lower) <When FS-535+PI-505 is installed> The tray upper limit sensor /Lw (PS209) or tray lower limit sensor /Lw (PS210) are not turned ON even after the set period of time has elapsed after the tray lift motor /Lw (M202) is energized.
Causes: • Tray lift motor /Lw (M202) • Tray upper limit sensor /Lw (PS209) • Tray lower limit sensor /Lw (PS210) • PI drive board (PIDB) • FS control board (FSCB)
Remedy: 1 Check the connector between M202-relay CN206- PIDB CN56 for proper connection, and correct as necessary. 2 Check the connector of M202 for proper drive coupling, and correct as necessary. 3 Check the connector between PS209-relay CN237- PIDB CN53<A> for proper connection, and correct as necessary. 4 Check the connector between PS210-relay CN236- PIDB CN53<A> for proper connection, and correct as necessary. 5 PS209 I/O check, sensor check PIDB CN53<A>-8 (ON) PI-505 8-C to D 6 PS210 I/O check, sensor check PIDB CN53<A>-11 (ON) PI-505 9-C to D 7 M202 operation check PIDB CN56-5 to 6 PI-505 7-C to D 8 Replace M202 9 PIDB ICP2 conduction check 10 Replace PIDB 11 Replace FSCB