Description: Charge cleaning motor/K’s malfunction During backward and return movement of the cleaner material, the charging cleaner home sensor is not blocked after a predetermined period of time has elapsed.
Remedy: 1 Check the drum unit for proper connection and correct as necessary. 2 Check the connector between M15-PHRYB CN12 for proper connection, and correct as necessary. 3 Check the M15 connector for proper connection and correct as necessary. 4 Check the connector between PS43-PHRYB CN2 for proper connection, and correct as necessary. 5 Check the connector between PS44-PHRYB CN2 for proper connection, and correct as necessary. 6 PS43 I/O check, sensor check PHRYB CN2-5 (ON) 10-B 7 PS44 I/O check, sensor check PHRYB CN2-8 (ON) 11-B 8 M15 operation check PHRYB CN12-1 to 2 9-B 9 Replace drum unit 10 Replace M15 11 PHRYB ICP1 conduction check 12 Replace PHRYB 13 Replace PRCB