Description: PH cooling fan’s failure to turn The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning.
Causes: • PH cooling fan (FM14) • PH relay board (PHRYB) • Printer control board (PRCB)
Remedy: 1 Check the connector between FM14-relay CN202- PHRYB CN12 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM14 operation check PHRYB CN12-8 (DRIVE) PHRYB CN12-9 (LOCK) 9-B 4 Replace FM14 5 PHRYB ICP1 conduction check 6 Replace PHRYB 7 Replace PRCB