Description: Take-up cooling fan’s failure. While the motor is running, the fan lock signal remains HIGH for a predetermined number of times in a row.
Causes: • Take-up cooling fan (FM1) • DF control board (DFCB)
Remedy: 1 Check the connector of FM1-DFCB CN9 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM1 operation check DFCB CN9-9 (LOCK) DF-702 4-C 4 Replace FM1 5 DFCB ICP5 conduction check 6 Replace DFCB