Code: C1132
Description: Punch drive motor’s malfunction Detection timing <When FS-534+PK-520 is installed> The punch home sensor (PS1) is not blocked or unblocked even after the set period of time has elapsed while the punch drive motor (M1) is energized. <When FS-535+PK-521 is installed> The PK punch home sensor/2 (PS301) is not blocked or unblocked even after the set period of time has elapsed while the punch drive motor (M301) is energized.
Causes: <When FS-534+PK-520 is installed> • Punch drive motor (M1) • Punch home sensor (PS1) • FS control board (FSCB) <When FS-535+PK-521 is installed> • Punch drive motor (M301) • PK punch home sensor/2 (PS301) • Punch control board (PKCB) • FS control board (FSCB)
Remedy: When FS-534+PK-520 is installed: 1 Check the connector between M1-relay CN351-FSCB J7 for proper connection, and correct as necessary. 2 Check the connector of M1 for proper drive coupling, and correct as necessary. 3 Check the connector between PS1-FSCB J7 for proper connection, and correct as necessary. 4 PS1 I/O check, sensor check FSCB J7-5 (ON) FS-534 (PK-520) 7-K 5 M1 operation check FSCB J7-7 to 8 FS-534 (PK-520) 7-K 6 Replace M1 7 Replace FSCB. When FS-535+PK-521 is installed: 1 Check the connector between M301-relay CN351- PKCB CN35 for proper connection, and correct as necessary. 2 Check the connector of M301 for proper drive coupling, and correct as necessary. 3 Check the connector between PS301-PKCB CN36 for proper connection, and correct as necessary. 4 PS301 I/O check, sensor check PKCB CN36-5 (ON) PK-521 3-C 5 M301 operation check PKCB CN35-1 to 3 PK-521 2-C 6 Replace M301 7 Replace PKCB 8 Replace FSCB