Mã lỗi C1140 — Konica-Minolta bizhub 754e

Code: C1140

Description: Alignment plate motor/Rr’s malfunction Detection timing <When FS-534 is installed> The alignment plate/R home sensor (PS13) is not blocked or unblocked even after the set period of time has elapsed while the alignment motor/Rr (M8) is energized. <When FS-535 is installed> The alignment plate motor home sensor/Rr (PS18) is not blocked even after the set period of time has elapsed while the alignment plate motor/Rr (M12) is energized.
Causes: <When FS-534 is installed> • Alignment motor/Rear (M8) • Alignment plate/R home sensor (PS13) • FS control board (FSCB) <When FS-535 is installed> • Alignment plate motor/Rr (M12) • Alignment plate motor home sensor/Rr (PS18) • FS control board (FSCB)
Remedy: When FS-534 is installed: 1 Check the connector between M8-FSCB J12 for proper connection, and correct as necessary. 2 Check the connector of M8 for proper drive coupling, and correct as necessary. 3 Check the connector between PS13-FSCB J9 for proper connection, and correct as necessary. 4 PS13 I/O check, sensor check FSCB J9<B>-9 (ON) FS-534 9-C 5 M8 operation check FSCB J12-13 to 16 FS-534 5 to 6-C to D 6 Replace M8 7 Replace FSCB. When FS-535 is installed: 1 Check the connector between M12-FSCB CN19 for proper connection, and correct as necessary. 2 Check the connector of M12 for proper drive coupling, and correct as necessary. 3 Check the connector between PS18-FSCB CN20 for proper connection, and correct as necessary. 4 PS18 I/O check, sensor check FSCB CN20-3 (ON) FS-535 11-D 5 M12 operation check FSCB CN19-5 to 8 FS-535 10-D 6 Replace M12 7 Replace FSCB

← Xem tất cả mã lỗi Konica-Minolta bizhub 754e

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie