Code: C3B07
Description: • IH input power error • Fusing unit for incorrect marketing area (The fusing unit for incorrect marketing area is installed) • IH power supply for incorrect marketing area (The IH power supply for incorrect marketing area is installed) Detection timing • While the IH heater was ON, input power stayed at the high voltage power detection value or over for more than the predetermined period of time. • While the IH heater was ON, input power was at the low power detection value or under for more than the predetermined period of time. • While the IH heater was ON, input power was at the high voltage detection value or over for more than the predetermined period of time. • While the IH heater was ON, input power was below the low voltage detection value or under for more than the predetermined period of time. • While the IH heater was ON, inverter power stayed at the upper limit value or over for more than the predetermined period of time. • While the IH heater was ON, output voltage halt was detected.
Causes: • Fusing unit • IH coil unit (IHC) • IH power supply (IHPU) • Noise filter (NF1) • Printer control board (PRCB)
Remedy: 1 Check the connection of the fusing unit. 2 Check the fusing unit, IHC, IHPU, NF1 and PRCB for proper connection and correct or change as necessary. 3 Check the marketing area of the fusing unit. If the marketing area is incorrect, replace the fusing unit for proper marketing area. 4 Check the marketing area of IHPU. If the marketing area is incorrect, replace IHPU for proper marketing area. 5 Replace IHC 6 Replace IHPU 7 Replace PRCB 8 Replace NF1