Code: C1113
Description: Stopper drive motor’s malfunction Detection timing <When FS-534+SD-511 is installed> <When FS-535+SD-512 is installed> The stopper home sensor (PS6) is not blocked or unblocked even after the set period of time has elapsed after the stopper drive motor (M4) is turned ON.
Causes: <When FS-534+SD-511 is installed> <When FS-535+SD-512 is installed> • Stopper drive motor (M4) • Stopper home sensor (PS6) • SD drive board (SDDB) • FS control board (FSCB)
Remedy: When FS-534+SD-511 is installed: 1 Check the connector between M4-SDDB J10 for proper connection, and correct as necessary. 2 Check the connector of M4 for proper drive coupling, and correct as necessary. 3 Check the connector between PS6-SDDB J10 for proper connection, and correct as necessary. 4 PS6 I/O check, sensor check SDDB J10-5 (ON) SD-511 2-G 5 M4 operation check SDDB J10-6 to 9 SD-511 1 to 2-F to G 6 Replace M4 7 Replace SDDB 8 Replace FSCB. When FS-535+SD-512 is installed: 1 Check the connector between M4-SDDB J10 for proper connection, and correct as necessary. 2 Check the connector of M4 for proper drive coupling, and correct as necessary. 3 Check the connector between PS6-SDDB J10 for proper connection, and correct as necessary. 4 PS6 I/O check, sensor check SDDB J10-5 (ON) SD-512 1-G 5 M4 operation check SDDB J10-6 to 9 SD-512 1-F to G 6 Replace M4 7 Replace SDDB 8 Replace FSCB