Code: C-0602
Description: PI-PFU (PF-703) dehumidifier fan /Lt1 (FM23) rotation abnormality. The FM23EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Dehumidifier fan /Lt1 (FM23: HT-505) • PF drive board (PFUDB: PF-703)