Code: C-0626
Description: PI-PFU (PF-703) dehumidifier fan /Lt3 (FM27) rotation abnormality. The FM27EM error detection signal is detected twice in succession within a specified period of time after FM27 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Dehumidifier fan /Lt3 (FM27: HT-505) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan heater, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 12-D) 3. Replace the fan heater (FM27). 4. Replace PFUDB.