Code: C-0637
Description: 1st tandem PF-703 dehumidification heater /1 (HTR1) high temperature hardware abnormality. The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON.
Causes: • Upper tray fan heater (HT-505) • AC drive board /2 (ACDB/2: HT-505) • PF drive board (PFUDB: PF-703)
Remedy: 1. Check the connection between ACDB/2 and the noise filter of PF-703. 2. Check the connector connection and the wiring between ACDB /2 and the fan heater, and repair it if any abnormality. 3. Check the connector connection and the wiring between PFUDB and the fan heater, and repair it if any abnormality. 4. Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. 5. Check the temperature and the installation of the fan heater, and repair it if any abnormality. 6. Replace the fan heater. 7. Replace ACDB/2. 8. Replace PFUDB.