Mã lỗi C-1106 — Konica-Minolta bizhub 951 Pro

Code: C-1106

Description: The stapler movement home sensor (PS22) does not turn ON within a specified period of time after the home position search operation of the stapler movement motor (M14) starts.
Causes: • FNS control board (FNSCB) • Stapler movement motor (M14) • Stapler movement home sensor (PS22) DIPSW35-0
Remedy: 1. Check the stapler movement section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between FNSCB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 5-F) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FS-532: 10-B) 5. Replace PS22. 6. Replace M14. 7. Replace FNSCB.