Mã lỗi C-1132 — Konica-Minolta bizhub 951 Pro

Code: C-1132

Description: The punch home sensor (PS301) does not turn ON within a specified period of time after the punch motor (M301) turns ON.
Causes: • FNS control board (FNSCB) • Punch drive board (PDB) • Punch motor (M301) • Punch HP sensor /1 (PS301) • Punch HP sensor /2 (PS307) DIPSW35-2
Remedy: 1. Check the punch kit, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. 3. Check the connector connection and the wiring between FNSCB and PDB and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PK:5-B) 5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 6. Replace M301. 7. Replace PS301 and PS302. 8. Replace PDB. 9. Replace FNSCB.