Code: C-1136
Description: After the punch switchover motor (M608) turns ON, punch switchover switch (MS601) does not turn ON from OFF, or not turn OFF from ON within a specified period of time.
Causes: • ZU control board (ZUCB) • Punch switchover motor (M608) • Punch switchover switch (MS601) DIPSW47-5
Remedy: 1. Check the connector connection and the wiring between ZUCB and motor/switch, and repair it if any abnormality. 2. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: ZU-608: 5-B) 3. Check I/O and the operation of the punch hole switching, and repair/replace it if any ab normality. (Wiring diagram: ZU-608: 5-B) 4. Replace MS601. 5. Replace M608. 6. Replace ZUCB.