Code: C-1175
Description: After the stopper motor (M105) turns ON, the stopper home sensor (PS107) does not turn ON within a specified period of time.
Causes: • FNS control board (FNSCB) • SD control board (SDCB) • Stopper motor (M105) • Stopper home sensor (PS107) DIPSW47-2
Remedy: 1. Check the connector connection and the wiring between SDCB and motor/sensor, and repair it if any abnormality. 2. Check the connector connection and the wiring between FNSCB and SDCB, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 1-G) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 6-B) 5. Replace PS107. 6. Replace M105. 7. Replace SDCB. 8. Replace FNSCB.