Code: C-1176
Description: After the center paddle motor (M106) turns ON, the center paddle home sensor (PS108) does not turn ON within a specified period of time.
Causes: • FNS control board (FNSCB) • SD control board (SDCB) • Center paddle motor (M106) • Center paddle home sensor (PS108) DIPSW47-2
Remedy: 1. Check the connector connection and the wiring between SDCB and motor/sensor, and repair it if any abnormality. 2. Check the connector connection and the wiring between FNSCB and SDCB, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 3-G) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-510: 4-B) 5. Replace PS108. 6. Replace M106. 7. Replace SDCB. 8. Replace FNSCB.