Code: C-1228
Description: The main tray upper limit sensor (PS20) does not turn ON within a specified period of time after the main tray home position search starts. Or, after the tray up down motor (M11) turns ON, the main tray upper limit sensor (PS20) does not turn OFF.
Causes: • Tray up down motor (M11) • Main tray upper limit sensor (PS20) • Punch drive board (PDB) DIPSW6-1
Remedy: 1. Check the punch alignment section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between FDB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FD-503: 3-D) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FD-503: 6-D) 5. Replace PS20. 6. Replace M11. 7. Replace PDB.