Code: C-1229
Description: The main tray lower limit sensor (PS22) does not turn ON within a specified period of time after the tray up down motor (M11) is in the down operation.
Causes: • Tray up down motor (M11) • Punch drive board (PDB) • Main tray lower limit sensor (PS22) DIPSW6-1
Remedy: 1. Check the punch alignment section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between FDB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: FD-503: 3-D) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: FD-503: 3-D) 5. Replace PS22. 6. Replace M11. 7. Replace PDB.