Code: C-1255

Description: The clincher up down home sensor (PS26) does not turn ON even after a specified period of time after the clincher up down motor (M20) starts the home position search. Or, even after a specified period of time after M20 starts the operation, it does not stop.
Causes: • Clincher up down motor (M20) • Clincher up down home sensor (PS26) • SD control board (SDCB) • SD drive board (SDDB) DIPSW7-0
Remedy: 1. Check the clincher up down section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. 3. Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-506: 16-D) 5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-506: 18-D) 6. Replace PS26. 7. Replace M20. 8. Replace SDDB. 9. Replace SDCB.