Code: C-1265
Description: It does not stop even after a specified period of time after the bundle arm assist motor (M26) starts the operation.
Causes: • Bundle arm assist motor (M26) • Bundle arm assist home sensor (PS38) • Bundle arm assist upper limit sensor (PS39) • SD control board (SDCB) • SD drive board (SDDB) DIPSW7-0, DIPSW7-1, DIPSW7-3
Remedy: 1. Check the bundle arm assist section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. 3. Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-506: 16-D) 5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-506: 17-D) 6. Replace PS38 or PS39. 7. Replace M26. 8. Replace SDDB. 9. Replace SDCB.