Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C-1266 — Konica-Minolta bizhub 951 Pro

Code: C-1266

Description: Rotation abnormality is detected for a specified period of time in succession while the entrance conveyance motor (M1) is driving.
Causes: • Entrance conveyance motor (M1) • SD control board (SDCB) • SD drive board (SDDB)
Remedy: 1. Check the entrance conveyance section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between SDDB and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:SD-506:2-D) 5. Replace M1. 6. Replace SDDB. 7. Replace SDCB.

← Xem tất cả mã lỗi Konica-Minolta bizhub 951 Pro