Code: C-1267
Description: Rotation abnormality is detected for a specified period of time in succession while the horizontal conveyance motor (M2) is driving.
Causes: • Horizontal conveyance motor (M2) • SD control board (SDCB) • SD drive board (SDDB) DIPSW7-4
Remedy: 1. Check the horizontal conveyance section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between SDDB and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-506: 7-D) 5. Replace M2. 6. Replace SDDB. 7. Replace SDCB.