Code: C-1273
Description: The trimmer completion sensor (PS62) does not turn ON even after a specified period of time after the trimmer blade motor (M31) is in the up operation.
Causes: • Trimmer blade motor (M31) • Trimmer completion sensor (PS62) • SD control board (SDCB) • SD drive board (SDDB) DIPSW7-3
Remedy: 1. Check the trimmer blade upper limit, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. 3. Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: SD-506: 22-R) 5. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: SD-506: 10-U) 6. Replace PS62. 7. Replace M31. 8. Replace SDDB.