Code: C-1281
Description: FD alignment motor (M3) drive abnormality. The CD alignment home sensor (PS3) does not turn ON even after a specified period of time after M3 starts the home position search operation. Or, even after a specified period of time after M3 starts the operation, it does not stop.
Causes: • FD alignment home sensor (PS3) • FD alignment motor (M3) • RU control board (RUCB)
Remedy: 1. Check the FD alignment section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between RUCB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: RU-510: 1-B) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: RU-510: 1-B) 5. Replace PS3. 6. Replace M3. 7. Replace RUCB