Code: C-1282
Description: CD alignment motor (M4): drive abnormality. The CD alignment home sensor (PS4) does not turn ON even after a specified period of time after M4 starts the home position search operation. Or, even after a specified period of time after M4 starts the operation, it does not stop.
Causes: • CD alignment home sensor (PS4) • CD alignment motor (M4) • RU control board (RUCB)
Remedy: 1. Check the alignment section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between RUCB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: RU-510: 2-B) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: RU-510: 5-B) 5. Replace PS4. 6. Replace M4. 7. Replace RUCB