Code: C-1353
Description: Error detection signals of FM15, FM16 and FM17 are detected continuously for a specified period of time while the entrance paper fans /4 (FM15), /5 (FM16) and /6 (FM17) are ON.
Causes: • Entrance paper fan /4 (FM15) • Entrance paper fan /5 (FM16) • Entrance paper fan /6 (FM17) • RU control board (RUCB)
Remedy: 1. Check the connector connection and the wiring between RUCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 17-L, 18-L) 3. Replace FM15, FM16 and FM17. 4. Replace RUCB