Code: C-1356
Description: An error detection signal of FM6 is detected continuously for a specified period of time while the humidification section paper fan /1 (FM6) is ON.
Causes: • Humidification section paper fan /1 (FM6) • RU control board (RUCB) • RU control board (RUCB) DIPSW13-2
Remedy: 1. Check the connector connection and the wiring between RUDB and the fan, and repair it if any abnormality. 2. Check the connector connection and the wiring between RUDB and RUCB, and repair it if any abnormality. 3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: RU-509: 19-O) 4. Replace FM6. 5. Replace RUDB. 6. Replace RUCB