Code: C-1515
Description: The glue tank movement operation has not been completed within a specified period of time after the glue tank movement motor (M31) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Glue tank movement motor (M31) DIPSW7-6
Remedy: 1. Check the glue tank movement section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 8-D) 5. Replace M31. 6. Replace PBDB1. 7. Replace PBCB.