Code: C-1517
Description: The count of a specified number of pellets, which is counted by the pellet supply passage sensor (PS37), has not been reached after the pellet supply pipe motor (M33) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Pellet supply pipe motor (M33) DIPSW7-6
Remedy: 1. Check the pellet supply section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 10-D) 5. Replace M33. 6. Replace PBDB1. 7. Replace PBCB.