Description: The transfer belt motor (M30) rotation abnormality. The M30EM error detection signal is detected twice in succession within a specified period of time after M30 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: • Transfer belt motor (M30) • ADU drive board (ADUDB) • Printer control board (PRCB)
Remedy: 1. Check the transfer belt, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between ADUDB and the motor, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (2/4): 6-P) 5. Replace M30. 6. Replace PRCB. 7. Replace ADUDB.