Code: C-2231
Description: De-curler motor (M32) rotation abnormality. The M32EM error detection signal is detected twice in succession within a specified period of time after M32 was turned ON, and the main door detection is Close.
Causes: • De-curler motor (M32) • ADU drive board (ADUDB) • Printer control board (PRCB)
Remedy: 1. Check the de-curler section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between ADUDB and the motor, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:Main body (2/4): 4-P) 5. Replace M32. 6. Replace PRCB.