Code: C-5102
Description: Monitor the detection signal of RL1 turning ON and 24 VICP blowout since the main tray (RL1) firstly turns ON after the power source turns ON, and detect the abonormality 5 times in a row during a specified period of time.
Causes: • Main relay (RL1) • AC drive board (ACDB)
Remedy: 1. Check the connector connection and the damage of PL1, and repair it if any abnormality. (Wiring diagram: Main body (1/4): 7-L) 2. Check the connector connection and the damage of ADCB, and repair it if any abnormality. (Wiring diagram: Main body (1/4): 1-F, 5-P, 22-M) 3. Replace RL1. 4. Replace ACDB.