Code: C-6103
Description: Scanner motor (M27) movement time abnormality. The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. At this time, an error detection signal (blowout of a fuse/24V cut off) of M27 is not detected.
Causes: • Scanner home sensor (PS51) • APS sensor /1 (PS52) • Scanner motor (M27) • Scanner drive board (SDB)
Remedy: 1. Check the scanner drive section, and repair it if any abnormality. 2. Check the connector connection and the wiring between SDB and motor/sensor, and repair it if any abnormality. 3. Check the I/O and drive of the sensor, and repair/replace it if any abnormality (Wiring diagram: Main body (4/4): 18-K, 20-N) 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality (Wiring diagram: Main body (4/4): 15-K) 5. Replace PS51 and PS52. 6. Replace M27. 7. Replace SDB.