Code: C4151
Description: Polygon motor rotation trouble (C)
• The polygon motor fails to turn stably even after the lapse of a given period of time after activating the polygon motor.
• Motor lock signal detects HIGH for a given period time consecutively during the polygon motor is rotating.
• The polygon motor fails to turn stably even after the lapse of a given period of time after activating the polygon motor.
• Motor lock signal detects HIGH for a given period time consecutively during the polygon motor is rotating.
Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change REYB/PH. 4 Change PRCB.