Code: C6751
Description: CCD clamp/gain adjustment failure
• The automatic gain control fails to converge when the main unit is started or a scan motion is started (the exposure unit does not move to the white reference position, or the automatic gain control is not properly completed as a result of a hardware failure).
• The automatic gain control fails to converge when the main unit is started or a scan motion is started (the exposure unit does not move to the white reference position, or the automatic gain control is not properly completed as a result of a hardware failure).
Remedy: 1 Correct the harness connection between CCDUB and BCRUB if faulty. 2 Check for possible extraneous light and correct as necessary. 3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty 4 Correct reflective mirror of the scanner if faulty, or change scanner. 5 Change BCRUB. 6 Change exposure unit.