Code: C0209
Description: LCT elevator motor failure
• The elevator motor pulse sensor (PS10) cannot detect both edges of H/L even after the set period of time has elapsed while the elevator motor (M5) is turning backward/forward (raise/lower).
• The elevator motor pulse sensor (PS10) cannot detect both edges of H/L even after the set period of time has elapsed while the elevator motor (M5) is turning backward/forward (raise/lower).
Remedy: 1 Check the connector between M5-REYB CN2 for proper connection and correct as necessary. 2 Check the connector between PS10-REYB CN2 for proper connection and correct as necessary. 3 Check the connector of each motor for proper drive coupling, and correct as necessary. 4 PS10 I/O check, sensor check. 5 M5 operation check. 6 Change REYB. 7 Change PCCB.