Code: C1190
Description: Alignment plate motor drive malfunction
<When FS-527 is installed> • The alignment plate home sensor (PS17) is turned neither ON nor OFF even after the set period of time has elapsed after the alignment plate motor (M13) is turned ON.
<When FS-527 is installed> • The alignment plate home sensor (PS17) is turned neither ON nor OFF even after the set period of time has elapsed after the alignment plate motor (M13) is turned ON.
Remedy: When FS-527 is installed: 1 Check the connector between M13-FSCB PJ8 for proper connection and correct as necessary. 2 Check the connector between PS17-FSCB PJ17 for proper connection and correct as necessary. 3 Check the connector of M13 for proper drive coupling, and correct as necessary. 4 PS17 I/O check, sensor check. 5 M13 operation check. 6 Change M13. 7 Change FSCB.