Code: C1194
Description: Leading edge stopper motor drive malfunction
<When FS-527 is installed> • The leading edge stopper home sensor (PS20) is turned neither ON nor OFF even after the set period of time has elapsed after the leading edge stopper motor (M14) is turned ON.
<When FS-529 is installed> • The leading edge stopper home sensor (PS14) is not turned OFF after the set period of time has elapsed after the stapler motor (M8) is turned ON.
<When FS-527 is installed> • The leading edge stopper home sensor (PS20) is turned neither ON nor OFF even after the set period of time has elapsed after the leading edge stopper motor (M14) is turned ON.
<When FS-529 is installed> • The leading edge stopper home sensor (PS14) is not turned OFF after the set period of time has elapsed after the stapler motor (M8) is turned ON.
Remedy: When FS-527 is installed: 1 Check the connector between M14-FSCB PJ8 for proper connection and correct as necessary. 2 Check the connector between PS20-FSCB PJ17 for proper connection and correct as necessary. 3 Check the connector of M14 for proper drive coupling, and correct as necessary. 4 PS20 I/O check, sensor check FSCB PJ17-6 (ON). 5 M14 operation check FSCB PJ8-9 to 12. 6 Change M14. 7 Change FSCB.
When FS-529 is installed: 1 Check the connector between M8-FSCB CN20 for proper connection and correct as necessary. 2 Check the connector between PS14-FSCB CN8 for proper connection and correct as necessary. 3 Check the connector of M8 for proper drive coupling, and correct as necessary. 4 PS14 I/O check, sensor check FSCB CN8-3 (ON). 5 M8 operation check. 6 Change stapler unit. 7 Change FSCB.
When FS-529 is installed: 1 Check the connector between M8-FSCB CN20 for proper connection and correct as necessary. 2 Check the connector between PS14-FSCB CN8 for proper connection and correct as necessary. 3 Check the connector of M8 for proper drive coupling, and correct as necessary. 4 PS14 I/O check, sensor check FSCB CN8-3 (ON). 5 M8 operation check. 6 Change stapler unit. 7 Change FSCB.