Code: C3101
Description: Fusing roller separation failure
• With the fusing roller being retracted, the pulse of the encoder sensor does not change even after the specified period of time has passed after the fusing pressure roller retraction motor started rotating. • With the fusing roller being pressed, the encoder pulse sensor does not change even after the specified period of time has passed after the fusing pressure roller retraction motor started rotating. • With the pressure roller being pressed, the fusing pressure roller home sensor did not turn ON (pressed) even after the fusing pressure roller retraction sensor counted up the specified number of pulse after the fusing pressure roller retraction motor started rotating.
• With the fusing roller being retracted, the pulse of the encoder sensor does not change even after the specified period of time has passed after the fusing pressure roller retraction motor started rotating. • With the fusing roller being pressed, the encoder pulse sensor does not change even after the specified period of time has passed after the fusing pressure roller retraction motor started rotating. • With the pressure roller being pressed, the fusing pressure roller home sensor did not turn ON (pressed) even after the fusing pressure roller retraction sensor counted up the specified number of pulse after the fusing pressure roller retraction motor started rotating.
Remedy: 1 Check the connector between M11-PRCB CN3 for proper connection and correct as necessary. 2 Check the connector between PS32-PRCB CN3 for proper connection and correct as necessary. 3 Check the connector between fusing unit- PRCB CN12 for proper connection and correct as necessary. 4 PS32 I/O check, sensor check PRCB CN3-9 (ON) C-13 5 M11 operation check PRCB CN3-5 to 6 C-13. 6 Change M11. 7 Change fusing unit. 8 PRCB ICP6 conduction check. 9 Change PRCB.