Description: Fusing motor turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the connector between M3-PRCB CN11 for proper connection and correct as necessary. 2 Check the loading status of the fusing unit drive, and correct the error as necessary. 3 M3 operation check PRCB CN11-9 (REM) PRCB CN11-12 (LOCK) J-6. 4 Change M3. 5 Change PRCB.