Description: Image input time out
• Image data is not input from the CCD board (CCDB) to the MFP board (MFPB).
Remedy: 1 Select [Service Mode] - [State Confirmation] - [Memory/HDD Adj.] - [Memory Bus Check] ?? [Scanner??Memory], and conduct the memory bus function. 2 Check the connectors between scanner section and MFPB for proper connection and correct as necessary. 3 Change MFPB. 4 Change CCDB.