Code: C3451
Description: Heat. Heater Trouble
• The Heating Roller Thermistor/1 (TH1) and the Heating Roller Thermistor/2 (TH3) fails to raise a given degree of temperature even after the lapse of a given period of time after the Heating Roller Heater lamp/1 (H1) is turned ON. • The detected temperature of the Heating Roller Thermistor/1 (TH1) is lower for a given level of degree than one of the Fusing Pressure Roller Thermistor/1 (TH2) after the Front Door is opened or closed, the Main Power Switch is turned ON or TROUBLE RESET is implemented. • The counter value of zero cross signal input is not updated for a given period of time.
• The Heating Roller Thermistor/1 (TH1) and the Heating Roller Thermistor/2 (TH3) fails to raise a given degree of temperature even after the lapse of a given period of time after the Heating Roller Heater lamp/1 (H1) is turned ON. • The detected temperature of the Heating Roller Thermistor/1 (TH1) is lower for a given level of degree than one of the Fusing Pressure Roller Thermistor/1 (TH2) after the Front Door is opened or closed, the Main Power Switch is turned ON or TROUBLE RESET is implemented. • The counter value of zero cross signal input is not updated for a given period of time.
Remedy: