Description: Tray 3/LCC vertical transport motor turning at abnormal timing (When PC-110, PC-210 or PC-410 is installed) • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: <When PC-110 or PC-210 is installed> • Tray 3 vertical transport motor (M112) • PC control board (PCCB) <When PC-410 is installed> • Vertical transport motor (M132) • PC control board (PCCB)
Remedy: When PC-110 or PC-210 is installed 1. Check the connector between M112-PCCB CN5 for proper connection and correct as necessary. 2. Check the connector of M112 for proper drive coupling and correct as necessary. 3. M112 operation check • Control signal: PCCB CN5-13 (CW/CCW) • Location of electrical component: PC-110/PC-210 3 to 4-C 4. Replace M112. 5. Replace PCCB. When PC-410 is installed 1. Check the connector between M132-PCCB CN5 for proper connection and correct as necessary. 2. Check the connector of M132 for proper drive coupling and correct as necessary. 3. M132 operation check • Control signal: PCCB CN5-13 (CW/CCW) • Location of electrical component: PC-410 4-J 4. Replace M132. 5. Replace PCCB.