Description: Tray 2 feeder up/down abnormality. The tray 2 upper limit sensor (PS22) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Remedy: 1. Remove the tray and check to see if a piece of paper is not left inside the machine. 2. Check the connector between M13-MFPB CN25E for proper connection and correct as necessary. 3. Check the connector of M13 for proper drive coupling and correct as necessary. 4. Check the connector between PS22-relay CN40-MFPB CN23E for proper connection and correct as necessary. 5. PS22 I/O check, sensor check • Control signal: MFPB CN23E-9 (ON) • Location of electrical component: 27-C 6. M13 operation check • Control signal: MFPB CN25E-5 (REM) • Location of electrical component: 22-C 7. Replace M13. 8. Replace MFPB.