Description: LCC shift failure (When PC-410 is installed) • The shifter stop / lower limit position sensor (PS138) is not turned ON (blocked) even after the set period of time has elapsed after the shift operation began (shift to the right). • The shifter home sensor (PS139) is not turned OFF (unblocked) even after the set period of time has elapsed after the shift operation began (shift to the right). • The shifter stop / lower limit position sensor (PS138) is not turned OFF (unblocked) even after the set period of time has elapsed after the return operation began (shift to the left). • The shifter home sensor (PS139) is not turned ON (blocked) even after the set period of time has elapsed after the return operation began (shift to the left).
Causes: • Shifter stop / lower limit position sensor (PS138) • Shifter home sensor (PS139) • Shifter motor (M133) • PC control board (PCCB)
Remedy: 1. Remove the tray and check to see if a piece of paper is not left inside the machine. 2. Check the connector between M133-PCCB CN10 for proper connection and correct as necessary. 3. Check the connector of M133 for proper drive coupling and correct as necessary. 4. Check the connector between PS138-relay CN16-PCCB CN14 for proper connection and correct as necessary. 5. Check the connector between PS139-relay CN16-PCCB CN14 for proper connection and correct as necessary. 6. PS138 I/O check, sensor check • Control signal: PCCB CN14-6 (ON) • Location of electrical component: PC-410 3-J 7. PS139 I/O check, sensor check • Control signal: PCCB CN14-3 (ON) • Location of electrical component: PC-410 4-J 8. M133 operation check • Control signal: PCCB CN10-3 to 4 • Location of electrical component: PC-410 6-J 9. Replace M133. 10. PRCB ICP2 conduction check 11. Replace PCCB.