Mã lỗi C1197 — Konica-Minolta bizhub C258

Code: C1197

Description: Tri-folding guide motor malfunction (When FS-534SD is installed) The tri-folding gate home sensor (PS11) is not turned ON (blocked) or OFF (unblocked) even after the set period of time has elapsed while the tri-folding guide motor (M6) is energized.
Causes: • Tri-folding guide motor (M6) • Tri-folding gate home sensor (PS11) • SD drive board (SDDB) • FS control board (FSCB)
Remedy: 1. Check the connector between M6-SDDB J9 for proper connection and correct as necessary. 2. Check the connector of M6 for proper drive coupling and correct as necessary. 3. Check the connector between PS11-SDDB J8 for proper connection and correct as necessary. 4. PS11 I/O check, sensor check • Control signal: SDDB J8-10 (ON) • Location of electrical component: SD-511 3-G 5. M6 operation check • Control signal: SDDB J9-7 to 10 • Location of electrical component: SD-511 4-F to G 6. Replace M6. 7. Replace SDDB. 8. Replace FSCB.