Description: • C3101: Pressure roller pressure failure • C3103: Pressure roller release failure. C3101: • The encoder pulse does not change even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during pressure by the pressure roller. • The fusing pressure home sensor (PS38) is not blocked even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during pressure by the pressure roller. C3103: • The encoder pulse does not change even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during retraction of the pressure roller. • The fusing pressure home sensor (PS38) is not unblocked even after the lapse of a predetermined period of time after the fusing pressure motor (M11) has started rotating during retraction of the pressure roller.
Causes: • Fusing unit • Fusing pressure motor (M11) • Fusing pressure home sensor (PS38) • MFP board (MFPB)
Remedy: 1. Check the connector between M11-MFPB CN15EA for proper connection and correct as necessary. 2. Check the connector between the fusing unit-relay CN98, CN99, CN104-MFPB CN13E for proper connection and correct as necessary. 3. PS38 I/O check, sensor check • Control signal: MFPB CN13E-12 (ON) • Location of electrical component: 11-C 4. M11 operation check • Control signal: MFPB CN15EA-5 to 8 • Location of electrical component: 6-C 5. Replace M11. 6. Replace the fusing unit. 7. Replace MFPB.